Intel® Pentium® III 1.26-GHz FC PGA2 Processor (dual capability)
ServerWorks LE 3.0 Chipset with 133-MHz Front Side Bus
PC133-MHz Registered ECC SDRAM memory
Integrated Smart Array Controller
Two full length expansion PCI slots: One 64-bit/33-MHz and one 32-bit/33-MHz
190-Watt Power Supply
512-KB level 2 ECC cache
128-MB PC133-MHz Registered ECC SDRAM memory, expandable to 4 GB
Two Compaq NC3163 Fast Ethernet NIC Embedded 10/100 WOL (Wake On LAN)
Wide Ultra2/Ultra3 SCSI Drive Cage standard supports up to two 1²
Wide Ultra2/Ultra3 hot plug hard drives
Internal hot plug capacity up to 145.6 GB (2 x 72.8 GB 1²
HD)
Exceptional serviceability with optional sliding rails, cable management and in-rack,
tool-free service ability access
Dual Peer PCI Bus Architecture for concurrent memory and processor access from PCI buses
Integrated Remote Console (IRC), Automatic Server Recovery-2 (ASR-2), Insight Manager
and SmartStart
Protected by HP Services, including a three-year, next business day on-site limited
global warranty and extended Pre-Failure Warranty which covers processors, memory, and
hard drives Certain restrictions and exclusions apply. Consult the Customer Support
Center at
1-800-345-1518 for details.
Two
Compaq NC3163 Fast Ethernet NIC (embedded) PCI 10/100 WOL (Wake On LAN)
Expansion
Slots
I/O (2
Total)
PCI
Voltage :
64-bit /33
MHz PCI
1
5 Volt or
universal cards
32-bit /33
MHz PCI
1
5 Volt or
universal cards
Manageability
Remote
Insight Lights-Out Edition
Note: Optional.
Storage
Controller
Integrated
Smart Array Controller
Note: This controller is embedded on
the system board.
Note: The Integrated Smart Array Controller only supports internal drives. The Smart Array
4200/5300 may bypass the Integrated Smart Array Controller and support internal drives
when configured with the ProLiantäDL360
Internal Array Controller Cabling Option Kit (PN 174571-B21).
Insight
Manager 7 helps maximize system uptime and performance and reduces the cost of maintaining
the IT infrastructure by providing proactive notification of problems before those
problems result in costly downtime and reduced productivity. Insight Manager 7 is easy to
set up and provides rapid access to detailed fault and performance information gathered by
the Management Agents. One-click access to the Integrated Lights-Out or Remote Insight
Lights Out Edition board allows systems administrators to take full graphical control of
ProLiant servers in remote locations or lights-out data centers. Finally, Insight Manager
7 in concert with the Version Control Agents and Version Control Repository Manager
enables systems administrators to version manage and update system software across groups
of ProLiant servers.
SmartStart
SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable and
consistent server configurations. For more information, please visit the SmartStart
website at http://www.compaq.com/smartstart.
SmartStart version supported (minimum): SmartStart 4.90 (up to 1.0-GHz Models)
SmartStart version supported (minimum): SmartStart 5.10 (1.13-GHz or greater Models)
Management
Agents
The
Management Agents form the foundation for HPs Intelligent Manageability strategy.
They provide direct, browser-based access to in-depth instrumentation built into HP
servers, workstations, desktops, and portables, and send alerts to Insight Manager 7 and
other enterprise management applications in case of subsystem or environmental failures.
For additional information about the Management Agents and other management products from
HP, please visit the management website at: http://www.compaq.com/manage
ActiveUpdate
ActiveUpdate
is a web-based application that keeps IT managers directly connected to HP for proactive
notification and delivery of the latest software updates.
ROMPaqä, support software, and configuration utilities
The
latest software, drivers, and firmware fully optimized and tested for your ProLiant server
and options.
Survey
Utility and diagnostics utilities
The
most advanced configuration analysis, reporting and troubleshooting utilities used by HP
and at your fingertips.
Optional
ProLiant Essentials Value Packs
Optional
software offerings that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
Rapid Deployment Pack an automated solution for multi-server deployment and
provisioning, enabling companies to quickly and easily adapt to changing business demands.
Workload Management Pack provides easier management of complex environments,
improving overall server utilization and enabling Windows® 2000 customers for
the first time to confidently deploy multiple applications on a single multiprocessor
ProLiant Server.
PXE
Support (supported with
9-1-2000 ROM or greater plus System Configuration Utility (2.54a or greater) from
SmartStart 5.0.)
WOL
Support
Microsoft®
Logo certifications
Manageability
Automatic
Server Recovery-2 (ASR-2)
Remote Insight Lights-Out Edition (optional)
Insight Manager 7
Management Agent
Integrated Remote Console (IRC)
Hardware Remote Console
Full Remote Server Reboot Capability
Reset and Failure Sequence Replay
Host Hardware Independent
Operating System Independent
Communication is out-of-band
Integrated Management Log
Drive Parameter Tracking (with Smart Array Controllers)
Dynamic Sector Repairing (with Smart Array Controllers)
Off-Line Backup Processor capability
Pre-Failure Warranty(covers processors, hard drives and memory)
Security
Power-on
password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Removable CD/Floppy Drive Assembly
Serial interface control
Administrator's password
Disk configuration lock
Server
Power Cords
One
Lowline power cord ships standard.
Power
Supply
Dual
Input Voltage, Auto-sensing 190-Watt, 292-Watt peak input, 3 integrated fans with failure
sensors, CE Mark Compliant
System
Fans
1
fan ships standard. 1 total supported internally.
Microsoft
Windows NT® Server
Microsoft Windows 2000
Novell® NetWare® 5.1
SCO® UnixWare®
LINUX® (Red Hat®, S.U.S.E. ®, TurboLinux Server,
Caldera® eServer)
Sun® Solarisä Intel Platform Edition
Note: For a more complete and
up-to-date listing of supported OSs and versions, please visit our OS Support Matrix page
at: ftp://ftp.compaq.com/pub/products/servers/os-support-matrix-310.pdf. Note: For a listing of
the latest drivers available for the Compaq ProLiant DL360, please see: http://www.compaq.com/support/files/server/us/index.html
Rack
Airflow Requirements
Rack 9000 and 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased
cooling efficiency for rack-mounted servers. The Compaq 9000 Series Rack and 10000 Series
Racks provides enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
Rack 7000 series Cabinets
When installing a server with processors running at speeds of 550 MHz or greater in
Compaq Rack 7000 series racks with glass doors (165753-001 (42U), and 163747-001 (22U)),
the new processor technology requires the installation of High Airflow Rack Door Inserts
( 327281-B21 (42U), 327281-B22 (42U 6 pack), or 157847-B21 (22U)) to promote enhanced
airflow for maximum cooling.
CAUTION: If a
third-party rack is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
Front and rear doors:
If your 42U server rack includes closing front and rear doors,
you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to
bottom to permit adequate airflow (equivalent to the required 64 percent open area for
ventilation).
Side:
The clearance between the installed rack component and the side panels of the
rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking panels to fill all remaining empty front panel
U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
Note: For additional information, refer to the Setup and Installation
Guide or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: http://www5.compaq.com/products/servers/proliantdl360/index2.html.
Service
and Support
HP
Services provides a three-year, limited warranty, including Pre-Failure Warranty (coverage
of hard drives, memory and processors) fully supported by a worldwide network of resellers
and service providers. HP technical assistance is available 7 x 24, toll free in the
United States and Canada. Telephone support services may be covered under warranty or
available for an additional fee.
Note: Limited Warranty includes 3 year Parts, 3 year Labor, 3-year
on-site support.
Installation and start up
Extended coverage hours and enhanced response times
System management and performance services
Availability and recovery services
Note: For more information,
customer/resellers can contact
Note:
Flexible and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.compaq.com/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
Note: For more information regarding ProLiant Essentials Software, please see the
following URL: http://www.compaq.com/proliantessentials.
NetServer to
ProLiant integrations services
HP NetServer to
ProLiant integration and assessment service
Note: HP identifies current levels
of NetServer support, services, and management. This service helps maximize
customers ability to add ProLiant platforms into their current environment
304164-002
HP TopTools to Insight
Manager 7 installation and startup service
Note: Provides on-site review,
installation and configuration services for Insight Manager 7. HP will also re-create, as
closely as possible, the views and reports from the customers current TopTools
configuration. This service assures a smooth transition to the ProLiant Essentials
software.
304163-002
HP NetServer to
ProLiant Essentials Rapid Deployment Pack installation and startup service
Note: Install and configure Rapid
Deployment Pack in a test environment, then deploy a server image to a maximum of 250
systems in the production environment. This service helps to assure successful system
deployment.
304162-002
Processor
Pentium III
P1266-512-KB Processor Option Kit
Note: When upgrading 550 MHz, 800
MHz, 866 MHz, 933 MHz, 1.0 GHz Models to a 1.133 GHz or 1.266 GHz Model, the Compaq
ProLiant DL360 P1133/P1266 Upgrade Kit (236122-B21) is required.
236121-B21
Pentium III
P1133-512-KB Processor Option Kit
Note: When upgrading 550 MHz, 800
MHz, 866 MHz, 933 MHz, 1.0 GHz Models to a 1.133 GHz Model, the Compaq ProLiant DL360
P1133 Upgrade Kit (236122-B21) is required.
232545-B21
Pentium III P1000-256KB
Processor Option Kit
Note: When upgrading 550 MHz, 800
MHz, 866 MHz, 933 MHz Models to a 1.0 GHz Model, the Compaq ProLiant DL360 P1000 Upgrade
Kit (225352-B21) is required.
256-MB
Battery-Backed Cache Module
Note: This 256-MB Battery-Backed
Cache Module supports the Smart Array 5300 series controllers, MSA 1000 and the Smart
Array Cluster Storage.
64-bit/66-MHz
Single Channel Wide Ultra3 SCSI Adapter
Note: For support of external
drives.
Note: This adapter will run
at 33-MHz speeds due to the 33-MHz PCI Bus.
64-bit/66-MHz
Dual Channel Wide Ultra3 SCSI Adapter
Note: For support of external
drives.
Note: This adapter will run at 33-MHz speeds due to the 33-MHz PCI Bus.
Note: Please see
the AIT 35-GB, LVD Tape Drive QuickSpecs for additional options such as adapters,
controllers, and cassettes, and for an up-to-date listing of the latest O/S Support
details, please see the following: http://www5.compaq.com/products/quickspecs/10712_na/
10712_na.html
HP StorageWorks AIT 50-GB Tape
Drive, External (Carbon)
157767-002
Note: Please see
the AIT 50-GB Tape Drive QuickSpecs for additional options such as adapters, controllers,
and cassettes, and for an up-to-date listing of the latest O/S Support details, please see
the following: http://www5.compaq.com/products/quickspecs/10425_na/
10425_na.html
HP StorageWorks External AIT
100-GB Tape Drive (Carbon)
Note:
Please see the AIT 100-GB Tape Drive QuickSpecs for additional options such as adapters,
controllers, and cassettes, and for an up-to-date listing of the latest O/S Support
details, please see the following: http://www5.compaq.com/products/quickspecs/11062_na/
11062_na.html
External
DLT/SDLT Tape Drives
HP StorageWorks 40/80-GB DLT Tape
Drive, External (Carbon)
Note: Please see
the 40/80-GB DLT Drive QuickSpecs for additional options such as host bus adapters,
controllers, cassettes, and for an up-to-date listing of the latest O/S Support details,
please see the following: http://www5.compaq.com/products/quickspecs/10658_na/
10658_na.html
Internal and
External DLT VS Tape Drives
HP StorageWorks DLT VS 40/80 Tape
Drive, Internal (Carbon)
Note: Please see
the DLT VS 40/80 Tape Drive QuickSpecs for additional options such as host bus adapters,
controllers, cassettes, and for an up-to-date listing of the latest O/S Support details,
please see the following: http://www5.compaq.com/products/quickspecs/11403_na/
11403_na.html
Note: Please see
the SDLT 160/320-GB Tape Drive QuickSpecs for additional options such as adapters,
controllers, and media, and for an up-to-date listing of the latest O/S Support details,
please see the following: http://www5.compaq.com/products/quickspecs/11406_na/
11406_na.html
Note: Please see
the SDLT 110/220-GB Tape Drive QuickSpecs for additional options such as adapters,
controllers, and media, and for an up-to-date listing of the latest O/S Support details,
please see the following:http://www5.compaq.com/products/quickspecs/10772_na/
10772_na.html
Note:
Please see the HP StorageWorks Ultrium 230 Tape Drive for ProLiant QuickSpecs for
additional options such as controllers, and other related items, and for an up-to-date
listing of the latest O/S Support details, please see the following: http://www5.compaq.com/products/quickspecs/11415_na/
11415_na.html
External AIT Autoloader
HP StorageWorks AIT 35 GB
Autoloader, Rackmount (Carbon)
280349-001
Note: Please see
the AIT 35-GB Autoloader QuickSpecs for additional options such as adapters, controllers,
and cassettes, and for an up-to-date listing of the latest O/S Support details, please see
the following: http://www5.compaq.com/products/quickspecs/11404_na/
11404_na.html
Rackmount Tape Drive Kits
3U Rackmount Kit
Note: The 3U Rackmount Kit (PN 274338-B21) can
support up to (2) full-height or (4) half-height tape drives and compatible with multiple
Single-Ended and LVD SCSI Tape Drives including the 12/24-GB DAT, 20/40-GB DAT, 20/40-GB
DAT DDS-4 8 Cassette Autoloader, AIT 35-GB LVD, AIT 50 GB, 20/40-GB DLT, 40/80-GB DLT, and
the SDLT 110/220-GB Tape Drives.
5U Rackmount Kit
Note: The 5U Rackmount Kit (PN 274339-B21) can
support up to (4) full-height tape drives and is compatible with all Compaq DLT/SDLT tape
drives including the 20/40-GB DLT, 35/70-GB DLT, 40/80-GB DLT, and the SDLT 110/220-GB
tape drives.
Note: Please see
the SSL2020 Automated AIT Tape Library Solution QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for
a complete solution at: http://www5.compaq.com/products/quickspecs/
10580_na/10580_na.html
Note: Please see
the StorageWorks MSL5026DLX or MSL5026SL Library QuickSpecs for additional
information including Upgrade Kits, Accessories, and SCSI Cable Kits and additional
options needed for a complete solution at: http://www5.compaq.com/products/quickspecs/10860_na/
10860_na.html
MSL5026SL, Rackmount, 1 SDLT
Drive (Graphite)
302512-B21
MSL5026SL, Rackmount, 2 SDLT
Drive (Graphite)
302512-B22
Note: Please see
the StorageWorks MSL5026SL Library QuickSpecs for additional information including
Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at: http://www5.compaq.com/products/quickspecs/11440_na/
11440_na.html
Note: Please see
the StorageWorks MSL5026S2 Library QuickSpecs for additional information including Upgrade
Kits, Accessories, and SCSI Cable Kits and additional options needed for a complete
solution at: http://www5.compaq.com/products/quickspecs/11453_na/
11453_na.html
Note: Please see
the StorageWorks MSL5052SL Library QuickSpecs for additional information including
Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at: http://www5.compaq.com/products/quickspecs/11061_na/
11061_na.html
Note:
Please see the StorageWorks MSL5052SL Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for
a complete solution at: http://www5.compaq.com/products/quickspecs/11061_na/
11061_na.html
Note: Please see
the StorageWorks MSL5052S2 Library QuickSpecs for additional information including
Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at: http://www5.compaq.com/products/quickspecs/11442_na/
11442_na.html
Note: Please see
the StorageWorks MSL5030 LTO Library QuickSpecs for additional information including
Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at: http://www5.compaq.com/products/quickspecs/11439_na/
11439_na.html
Note: Please see
the StorageWorks MSL5060 LTO Library QuickSpecs for additional information including
Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at: http://www5.compaq.com/products/quickspecs/11438_na/
11438_na.html
Note:
Options include controller, solution kits, ACS. MA8000/EMA12000 includes controller shelf,
drive shelves and cabinet. Packaging upgrade to RA8000/ESA12000.
Note: Models
include: Dual HSG80 controllers in each Model 2200 enclosure (2 pairs per single bus
configuration, 4 pairs per dual bus configuration) with 1GB cache per controller pair, and
12 14-bay drive enclosures with redundant power supplies. Configure-to-Order (CTO) builds
are available. Options include ACS, platform kits and SANworks software by
Compaq.
Note: Please see the StorageWorks EMA16000 QuickSpecs for FC switches, platform
software, host adapters, disks and options for complete solutions at: http://www5.compaq.com/products/quickspecs/10812_na/
10812_na.html
StorageWorks Options
Fibre Channel SAN Switch/8 with
Fabric Operating Software
Rack-Mountable
PDUs 1U/0U (up to 12 outlets)
Note: 0U mounting brackets shipped
with the unit (separate option kit for 1U mounting).
Compaq Power
Distribution Unit-16A (200 to 240V)
Note: The 16A PDU also connects to
the high volt models of the UPS R3000 XR (need cable PN 340653-001) and the UPS R6000
models. Cable PN 340653-001 required if connecting to UPS R3000 XR ( 192186-002 -High Volt
model only).
207590-B21
Compaq Power
Distribution Unit-24A (200 to 240V)
Note: This PDU may also be used to
connect to the low volt UPS R3000 XR model.
207590-D72
Compaq Power
Distribution Unit-40A (200 to 240V)
207590-B23
Compaq Power
Distribution Unit-24A (100 to 127V
207590-D71
1U PDU Mounting
Brackets
Note: The 1U PDU Mounting Brackets
are required when mounting PDUs PN 207590- series in 1U configurations.
Modular
PDUs 1U/0U (up to 32 outlets)
Note: 1U/0U mounting brackets
shipped with the unit (optimized for 10000 and 9000 series racks).
Modular Power
Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
Note: This mPDU ( 252663-D71) may
also be used to connect the low volt model of the UPS R3000 XR.
Note:
-B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs
and Channels)
-B23 (crated) used for air shipments of empty racks
Note: It is mandatory to use a shock pallet in order to ship racks with equipment
installed. Not all
Compaq equipment is qualified to be shipped in the Rack 10000 series.
Note:
-B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs
and Channels)
-B23 (crated) used for air shipments of empty racks **Not all Compaq equipment is qualified to be shipped in the Rack 9000 Series.
Rack Options for
Compaq Rack 10000 Series
Rack Blanking Panels
Graphite (Multi)
Note: Contains one each of 1U, 2U, 3U, and 4U
panel.
253214-B26
Rack Blanking Panels
Graphite (1U)
Note: The Rack Blanking Panels (PN
253214-B21) contains 10 each of (1U).
253214-B21
Rack Blanking Panels
Graphite (2U)
Note: The Rack Blanking Panels (PN
253214-B22) contains 10 each of (2U).
253214-B22
Rack Blanking Panels
Graphite (3U)
Note: The Rack Blanking Panels (PN
253214-B23) contains 10 each of (3U).
253214-B23
Rack Blanking Panels
Graphite (4U)
Note: The Rack Blanking Panels (PN
253214-B24) contains 10 each of (4U).
253214-B24
Rack Blanking Panels
Graphite (5U)
Note: The Rack Blanking Panels (PN
253214-B25) contains 10 each of (5U).
9000/10000 Series
Offset Baying Kit (42U)
Note: This kit can be used to connect 9000 and
10000 series racks of the same U height together. Kit contents include hardware for
connecting racks and a panel to cover the 100-mm gap at the rear of the two racks.
248931-B21
Rack Options for
Compaq Rack 9000 Series
Baying/Coupling Kit
120669-B21
42U Side Panel
Note: The 42U Side Panel (PN 120670-B21)
supports the Compaq Rack 9142 and Compaq Rack 9842.
Rack Blanking Panels (4U)
Note: The Rack Blanking Panels (PN
189453-B24) contains 10 each of (4U).
189453-B24
Rack Blanking Panels (5U)
Note: The Rack Blanking Panels (PN
189453-B25) contains 10 each of (5U).
189453-B25
9000/10000 Series Offset Baying
Kit (42U)
Note: This kit can be used to connect 9000 and
10000 series racks of the same U height together. Kit contents include hardware for
connecting racks and a panel to cover the 100-mm gap at the rear of the two racks.
1U Rack Keyboard &
Drawer (Carbon)
Note: The 1U Rack Keyboard &
Drawer
(PN 257054-001) is to be used with the Keyboards for Racks with Trackball (PN 158649-001).
5 x 9 Coverage, 3
Years (6-3 Part Number for U.S.)
162676-002
5 x 9 Coverage, 3
Years (6-3 Part Number for Canada)
162676-122
7 x 24 Coverage, 3
Years (6-3 Part Number for U.S.)
162675-002
7 x 24 Coverage, 3
Years (6-3 Part Number for Canada)
162675-122
Installation & Start-up
Services
Hardware Installation
(6-3 Part Number for U.S.)
401791-002
Hardware Installation
(6-3 Part Number for Canada)
401791-122
Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to server at
same time of server installation; assemble & test; basic user information provided;
Install & configure basic functionality of Win NT Operating System plus up to 2 days
start-up activity, configure print & network access services, and orientation (6-3
Part Number for U.S.)
240013-002
Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to server at
same time of server installation; assemble & test; basic user information provided;
Install & configure basic functionality of Novell NetWare Operating System plus up to
2 days start-up activity, configure print & network access services, and orientation
(6-3 Part Number for U.S.)
240008-002
CarePaq Priority Services
for ProLiant Servers Priority Level
9 x 5 HW, 4-hr
response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System, Next
Available Specialist (6-3 Part Number for U.S.)
239928-002
9 x 5 HW, 4-hr
response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response for
Novell NetWare Operating System, Next Available Specialist (6-3 Part Number for U.S.)
239968-002
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (6-3 Part Number for Canada)
155323-122
CarePaq Priority Services
for ProLiant Servers Priority 24 Level
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr response for Windows NT,
Windows 2000, Professional, Server or Advanced Server Operating System, Next Available
Specialist (6-3 Part Number for U.S.)
239930-002
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr response for Novell
NetWare Operating System, Next Available Specialist (6-3 Part Number for U.S.)
239970-002
CarePaq Priority Services
for ProLiant Servers Priority Plus Level
7 x 24 4-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS account review, Three Years (6-3 Part Number for
Canada)
155331-122
CarePaq Priority Services
for ProLiant Servers Priority Silver
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response, Monday
Friday, 8AM 5PM local time, 2-hr response after hours for Windows NT, Windows 2000,
Professional, Server or Advanced Server Operating System, Technical Account Manager,
Technical Newsletter, SW activity review, proactive patch notification, 1 System
Healthcheck per year (6-3 Part Number for U.S.)
239932-002
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Silver Sulbequent System Support for Windows NT,
Windows 2000, Professional, Server or Advanced Server Operating System (6-3 Part Number
for U.S.)
239934-002
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response, Monday
Friday, 8AM 5PM local time, 2-hr response after hours for Novell NetWare Operating
System, Technical Account Manager, Technical Newsletter, SW activity review (6-3 Part
Number for U.S.)
239972-002
24 x 7 HW, 4-hr
response, Named HW engineer; 24 x 7 Silver Sulbequent System Support for Novell NetWare
Operating System (6-3 Part Number for U.S.)
239974-002
CarePaq Priority Services
for ProLiant Servers Priority Premier Level
7 x 24 2-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS Account Review, Proactive Management Review, named
S/w rep, Three Years (6-3 Part Number for Canada)
155335-122
CarePaq Priority Services
for ProLiant Servers Priority Executive Premier Level
7 x 24 2-hour H/W, 7
x 24 30-minutes O/S (NT & NetWare), SPS Account Review, Proactive Management Review,
named S/w rep, Three Years (6-3 Part Number for Canada)
Standard Memory 128-MB PC133-MHz Registered ECC SDRAM DIMM installed (1 x 128-MB SDRAM DIMM)
Standard Memory Plus Optional Memory
Up to 3200-MB memory is available with the optional installation of PC-133 MHz
Registered ECC SDRAM DIMM memory kits.
Standard Memory Replaced with Optional Memory
Up to 4096-MB of memory is available with the removal of the standard 128-MB of memory
and the optional installation of PC133-MHz Registered ECC SDRAM DIMM memory kits.
Note: Chart does not represent
all possible configurations.
Memory
Slot
1
2
3
4
Standard
128 MB
128
MB
Empty
Empty
Empty
Optional
3200 MB
128
MB
1024
MB
1024
MB
1024
MB
Maximum
4096 MB
1024
MB
1024
MB
1024
MB
1024
MB
Following are memory
options available from Compaq:
No hard
drives installed, one power supply
Hard drives installed, one power supply
26 llb/11.81 kg
28.6 llb/13 kg
Input Requirements
Range Line Voltage
100 to 240 VAC
Nominal Line Voltage
100 to 120 VAC/220 to
240 VAC
Rated Input Current
2.66A (110 V) to
1.33A (220 V)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
292 W
Note: 292 W of Rated Input Power is for
the Maximum Peak Output Power of 190 W.
BTU Rating
996 BTUs/hr
Note: The BTU Rating listed is for the
Rated Input Power of 292W.
Power Supply
Output Power (per power supply)
Rated Steady-State
Power
170W
Note: The Steady State Power of 170 W
is when the ProLiant DL360 is fully loaded with two 800-MHz processors, four 1024-MB
DIMMs, two 10,000 rpm drives, a Remote Insight Lights-Out Edition and a Smart Array 4200
Controller.
Maximum Peak Power
190W
Temperature Range
Operating
50° to 95° F/
10° to 35° C
Shipping
-22° to 122° F/
-30° to 50° C
Relative
Humidity
(non-condensing)
Operating
8% to 90%
Shipping
5% to 95%
Maximum Wet Bulb
Temperature
101.7°F/38.7°C
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
L WAd
(BELS)
6.5
L pAm
(dBA)
51
Operating
(Random Seeks to Fixed Disks)
L WAd
(BELS)
6.6
L pAm
(dBA)
52
1.44-MB Diskette
Drive
Diskette Size
3.5 in
LED Indicators (front
panel)
Green
Read/Write
Capacity per
Diskette (high/low density)
Note:
For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2.
Channels
2
Note:
For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2. The second channel
on the DL360 is for external tape support only.
SCSI Ports (external/internal)
1/1
Note:
For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2. The DL360 has a
SCSI port at the back of the server for external tape support only.
Drives Supported (maximum)
Maximum = total
number of internal drives
Note:
Maximum is the total number of internal drives on each specific ProLiant server.
Cache
8-MB read only
RAID Support
0, 1, 1+0, 5
Note:
RAID 5 is not supported on the Compaq ProLiant DL360. A minimum of three drives is
required for RAID 5 and the Compaq ProLiant DL360 only supports up to two.
Logical Drives (maximum)
32
Online
Configuration
Yes
Online Capacity
Expansion
Yes
Logical Drive
Capacity Extension
Yes
Online Stripe Size
Migration
Yes
Online RAID Level
Migration
Yes
Online Spare
Support
Yes
Automatic Data
Recovery
Yes
Drive Roaming
Yes
Redundant
Controllers
No
Two Compaq NC3163
Fast Ethernet NIC Embedded 10/100 WOL (Wake On LAN)
Network Interface
10Base-T/100Base-TX
Compatibility
IEEE 802.3/802.3u
compliant
Data Transfer
Method
32-bit bus-master PCI
Network Transfer
Rate
10Base-T
(Half-Duplex)
10 Mb/s
10Base-T
(Full-Duplex)
20 Mb/s
100Base-TX
(Half-Duplex)
100 Mb/s
100Base-TX
(Full-Duplex)
200 Mb/s
Connector
RJ-45
Cable Support
10Base-T
Categories 3, 4 or 5
UTP; up to 328 feet (100 meters)
100Base-TX
Category 5 UTP; up to
328 feet (100 meters)
Video Controller
Controller Chip
ATI RAGE IIC PCI
Video DRAM
4-MB Video SDRAM
Data Transfer
Method
32-bit PCI
Support Resolution
Supported Color
Depths:
640 x 480
16.7M, 64K, 256, 16
800 x 600
16.7M, 64K, 256, 16
1024 x 768
16.7M, 64K, 256, 16
1152 x 864
16.7M, 64K, 256, 16
1280 x 1024
16.7M, 64K, 256, 16
1600 x 1200
64K, 256, 16
Connector
VGA
Smart Array 5300
Controller
Data Compatible
with all Smart Array Controllers
Yes
Instant Upgrades
to other Smart Array Controllers
Yes
Consistent
Software Manageability Tools
Yes
PCI Bus
64-bit, 66 MHz
PCI Peak Data
Transfer Rate
533 MB/s
SCSI Protocols
Supported
Ultra3, Ultra2,
Wide-Ultra
SCSI Peak Data
Transfer Rate
640 MB/s total, 160
MB/s per channel
Channels
2, 4
SCSI
Ports (external/internal)
2 channel
model: 2/2
4 channel model: 4/2
Drives
Supported (maximum)
56
Note: Drives Supported (maximum) is based on use of StorageWorks
Enclosure 4200/4300 family (14 hard disk drive enclosure).
Cache
256, 128, 64 or 32 MB
battery backed read-write
RAID Support
0, 1, 1+0, 5,
Advanced Data Guarding
Note: For customers who have purchased the SA-5304/128 a quick firmware
upgrades to enable the technology is available from http://www.compaq.com/smartarray.
Note: RAID Support: Advanced Data Guarding (RAID ADG) is available with
128-MB versions of the SA-5300 only.
Logical Drives (maximum)
32
Online
Configuration
Yes
Online Capacity
Expansion
Yes
Logical Drive
Capacity Extension
Yes
Online Stripe Size
Migration
Yes
Online RAID Level
Migration
Yes
Online Spare
Support
Yes
Automatic Data
Recovery
Yes
Drive
Roaming
Yes
Redundant
Controllers
No
64-bit/66-MHz
Single Channel Wide Ultra3 SCSI Adapter
Drives Supported
Up to 14 SCSI devices
Storage Capacity
254.8 GB
Data Transfer Method
64-bit/66-MHz PCI bus-master
(The Compaq ProLiant DL360 PCI bus
operates at 33 MHz.)
Maximum SCSI Channel Transfer
Rate
160 MB/s per channel
Maximum Transfer Rate per PCI
Bus (peak)
532 MB/s per channel
SCSI
Protocols
Wide Ultra3 SCSI
Wide Ultra2 SCSI
Wide-Ultra SCSI-3
Fast-Wide SCSI-2
Fast SCSI-2
Electrical Protocol
Low Voltage Differential (LVD)
SCSI Termination
Active Termination
External SCSI Connectors
One 68-Pin Wide Ultra SCSI-3
connector
Internal SCSI Connectors
Two 68-Pin Wide Ultra SCSI-3
connectors (one LVD and one SE)
One 50-Pin Narrow Ultra connector