Choice
of Smart Array P400i Controller or Smart Array E200i Controller
5.
NIC
2 connector
6.
NIC
1 connector
6.
Redundant
Hot Plug Power Supplies
7.
Keyboard
connector
7.
Full
length/height x8 PCI-Express Slot (optional PCI-X)
8.
Mouse
connector
8.
Low-profile
x4 PCI-Express slot
9.
Video
connector
9.
Eight
PC2-5300 667 MHz DDR2 DIMM slots
10.
Serial
connector
10.
Up
to two AMD Opteron™ processors
11.
USB
connector
12.
USB
connector
13.
iLO
2 NIC connector
At
A Glance
A concentrated 1U server that delivers the right match of processing
power, memory performance, I/O throughput, scalability, HP Insight Control
, and essential fault tolerance. The HP ProLiant DL365 G5 is optimized
for space constrained scaling installations. Quad-Cord AMD Opteron™
processors, DDR2 memory, Serial Attached SCSI (SAS) and PCI Express technology
provide a high performance system ideal for the full range scale out applications.
What's more, the DL365 G5 provides all this in an ultra-dense platform
with redundant power, fans, and embedded RAID capability.
Processors:
Up to 2 AMD Opteron™ 2300 Series Quad-Core processors, with
512 KB L2 Cache per core, 2 MB L3 Cache
Supports DirectConnect Architecture and HyperTransport Technology
Supports AMD PowerNow!™ Technology
Memory:
Up to 32 GB of memory, supported by 8 slots of either PC2-5300 DDR2
(667 MHz) or PC2-6400 DDR2 (800 MHz) depending on the processor
Base and High Efficiency Models: HP Smart Array P400i/256MB Controller
(RAID 0/1/1+0/5) (512MB BBWC optional)
Performance Models: HP Smart Array P400i/256MB Controller with BBWC
(RAID 0/1/1+0/5)
Internal Drive Support:
Up to 6 small form factor (SFF) hot-plug drive bays
Slimline media bay supporting DVD or CD drive
Network Controller:
Two embedded NC373i Multifunction Gigabit Network Adapters with
TCP/IP Offload Engine, including support for Accelerated iSCSI through
an optional Licensing Kit
Multiple layers of fault tolerance through critical component redundancy
(power supply and fan redundancy), embedded RAID capability, and full-featured
ProLiant Onboard Administrator
Infrastructure Management:
Convenient slide-out Systems Insight Display for quick and easy
front view server diagnostics, along with status LEDs, Automatic
Server Recovery (ASR), ROM Based Setup Utility (RBSU)
HP ProLiant Onboard Administrator (powered by the Integrated Light-Out
2 management processor) for simplified server setup, health monitoring
and recovery, power and thermal control, and lights-out remote administration
HP Insight Control (ICE) suites, as product options, deliver essential
infrastructure management that can help save time and money by making
it easy to deploy, monitor, control and optimize your IT infrastructure
through a single, simple management console. ICE suites support
both Windows and Linux-based servers and management consoles.
HP Insight Dynamics - VSE suite for ProLiant servers, a product
option, is an integrated command center that enables you to continuously
analyze and optimize your adaptive infrastructure. This advanced
infrastructure management software lets you reduce the cost of common
data center tasks by as much as 40 percent while keeping pace with
your changing business
Form Factor:
1U Rack form factor (1.75"), less than 28 in (70.5 cm) deep
Operating Systems and Virtualization Software Support for ProLiant
Servers:
Sliding rails for in rack servicing ship standard; optional 1U Cable
Management Arm
Customer Self Repair (CSR): HP products are designed with many CSR
parts to minimize repair time and allow for greater flexibility in
performing defective parts replacement
Warranty:
This product is covered by a global limited warranty and supported
by HP Services and a worldwide network of HP Authorized Channel
Partners resellers. Hardware diagnostic support and repair is available
for three years from date of purchase. Support for software and
initial setup is available for 90 days from date of purchase. Enhancements
to warranty services are available through HP Care Pack services
or customized service agreements. Hard drives have either a one
year or three year warranty; refer to the specific hard drive QuickSpecs
for details. NOTE: Server Warranty includes
3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business
day response. Warranty repairs may be accomplished through the use
of Customer Self Repair (CSR) parts. These parts fall into two categories:
1) Mandatory CSR parts are designed for easy replacement. A travel
and labor charge will result when customers decline to replace a
Mandatory CSR part; 2) Optional CSR parts are also designed for
easy replacement but may involve added complexity. Customers may
choose to have HP replace Optional CSR parts at no charge. Additional
information regarding worldwide limited warranty and technical support
is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
NOTE:
For a brief, printer friendly data sheet that describes this product and
informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA1-5214ENW.pdf. NOTE: For the Standard Features shipped in the "Factory Integrated
Models", please see the "Configuration Information - Factory Integrated
Models" section.
Processor One of the following depending on Model
AMD
Opteron™ Processor 2384 (2.7 GHz, 75 Watts)
AMD
Opteron™ Processor 2382 (2.6 GHz, 75 Watts
AMD Opteron™ Processor
2378 (2.4GHz, 75 Watts)
AMD
Opteron™ Processor 2356 (2.3 GHz, 75 Watts)
AMD
Opteron™ Processor 2354 (2.2 GHz, 75 Watts)
AMD
Opteron™ Processor 2352 (2.1 GHz, 75 Watts)
AMD
Opteron™ Processor 2346 HE (1.8GHz, 55 Watts)
Chipset
Serverworks HT-2100 Northbridge
and HT-1000 Southbridge Chipset
NOTE:
DIMMs must be installed in decreasing capacity with the largest DIMM installed
in the banks furthest away from each processor.
Network
Controller
Two embedded NC373i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit
Expansion
Slots
Expansion
Slots #
Technology
Bus Width**
Connector Width
Bus Number*
Device
No.**
Form Factor
Notes
1
PCI-e
x4
x8
72
0
Low profile slot
2
PCI-e
x8
x16
75
0
Full length, full height slot
2
PCI-X (133MHz, 3.3 Voltage)
64-bit
x16
2
1
Full length, full height slot
*
Default bus assignment (in decimal). Inserting cards with PCI bridges may
alter the actual bus assignment number ** Slots are enumerated differently
based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting
with the lowest bus). *** Indicates the number of physical electrical lanes
running to the connector.
Manageability
HP Insight Control suite: essential management, including proactive
health management, lights out remote control, optimization of power
usage, rapid server deployment, performance analysis, vulnerability
scanning and patch management and virtual machine management. For more
information, go to: www.hp.com/go/ice.
HP ProLiant Onboard Administrator (powered by the Integrated Light-Out
2 management processor) for simplified server setup, health monitoring
and recovery, power and thermal control, and lights-out remote administration
Storage Controllers One of the following depending on Model
Entry Models
HP Smart Array E200i/64 MB Controller
(RAID 0/1) Available upgrade: 128 MB memory module with battery-backed write
cache (BBWC) for RAID 0/1/5.
Base and High Efficiency Models
HP Smart Array P400i/256MB Controller
(RAID 0/1/1+0/5) (512MB BBWC optional)
Performance Models
HP Smart Array P400i/256MB Controller
with BBWC (RAID 0/1/1+0/5)
Storage
Optical
Drives (Slimline Drive bay)
Optional
DVD-ROM, DVD/CD-RW Combo, or DVD-RW
Drive
Bays
6 Small Form Factor bays
total
NOTE:
4 bays active in most models. Smart Array P400i controller and Mini-SAS storage
cable (P/N 399546-B21) required for activation of 5th and 6th drive bays.
NOTE: Maximum resolution
available via iLO 2 remote console is 1280 x 1024.
Form Factor
Rack (1U), (1.75 in/4.45 cm)
HP Insight Software
HP Insight Foundation
Managing the growing number of servers can be complex and expensive for
your organization. IT managers need to address changing business needs
with tools that meet the challenges of managing today's complex Datacenters.
HP provides management solutions that are designed to simplify a server's
installation, configuration and maintenance throughout the entire server
lifecycle. This provides the customer with higher levels of operational
efficiency and highly reliable systems: www.hp.com/go/foundation.
HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out
2 management processor) simplifies server setup, health monitoring, power
and thermal control, and lights-out remote administration of ProLiant
ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without
additional software, and can be accessed from any location via a web browser.
It works hand-in-hand with HP Systems Insight Manager, Insight Control
suites, and the Insight Dynamics-VSE suite helping customers unlock the
value of the ProLiant platform and deliver the highest possible quality
of IT service to the business. See www.hp.com/go/ProLiantOA
HP Insight Control suites
HP Insight Control suites, as product options, deliver essential infrastructure
management that can help save time and money by making it easy to deploy,
monitor, remote control, and optimize your IT infrastructure through a
single, simple management console. Insight Control suites install and
license software modules that are integrated into HP System Insight Manager.
Two Insight Control suites are available, to serve environments requiring
either Linux-based or Windows-based management consoles: HP Insight Control
suite for Linux, and HP Insight Control suite. See www.hp.com/go/insightcontrol
HP Insight Control suites include one year of 24 x 7 HP Software Technical
Support and Update Service ensuring rapid access to HP support staff and
proactive delivery of software updates. For more information about this
service, please visit: http://www.hp.com/services/insight.
HP Insight Dynamics - VSE suite
The HP Insight Dynamics - VSE
suite for ProLiant, a product option, is an integrated command center that
enables you to continuously analyze and optimize your adaptive infrastructure.
This advanced infrastructure management software that allows you to analyze
and optimize your adaptive infrastructure to manage physical and virtual
resources in the same way. HP Insight Dynamics - VSE gives you a powerful
toolkit to accelerate complex technology projects and simplify daily operations.
It enables you to plan capacity and power continuously, balance across physical
and virtual resources, ensure cost-effective high availability, and provision
infrastructure consistently.
HP Insight Orchestration, an optional extension to Insight Dynamics - VSE,
enables IT organizations to provision infrastructure consistently and automatically
from pools of shared resources using a self-service portal. Resources provisioned
can range from a single virtual machine to complex multi-tier environments
and their associated physical and virtual resource requirements.
HP Insight Recovery, also an optional extension for Insight Dynamics - VSE,
enables cost-effective disaster recovery for physical and virtual environments.
Application environments can be reactivated in minutes with the touch of
a button to a remote location
HP Systems Insight Manager
SmartStart
ROM-Based Setup Utility (RBSU)
Remote-Flash Redundant ROM
Integrated Management Log (IML)
Server Health logging
Automatic Server Recovery-2 (ASR-2)
System Interconnect Status Indicators
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Power Down Utility
Pre-Failure Warranty
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Removable CD and Diskette Drive Assembly
Serial interface control
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
iLO Advance Pack supports directory services integration and two-factor authentication
Server Power Cords
High line
cord ships standard with all part numbers. Localized cables included with geographic
specific models in other world regions. NOTE:
ProLiant DL servers no longer ship standard with NEMA power cords (187335-001)
that allow connection to 110V US wall outlets in a home or office. ProLiant DL
servers are primarily connected to PDU's in data center racks so they now ship
standard with only a PDU power cord (416151-B21). If a user wishes to power a
ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord (187335-001)
must be ordered separately.
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable
matrix's on the HP Power Protection and Management page. Under Power Cords,
click on the "HP Power Cord Matrix" link. That link will list
cable descriptions, requirements, and specifications for UPS and PDU units.
Please see the following link: www.hp.com/products/powercords.
Power Supply
700 W, Optional
(1+ 1 redundant) power supply NOTE:
PN 399542-B21 contains the optional power supply and an IEC power cable only;
purchase if connecting to PDU/UPS that supports IEC cables. PN 399542-291 includes
IEC power cable and a Japan power cable. PN 399542-AA1 includes IEC power cable
and a China power cable.
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for
OS and Virtualization Software and latest listing of software drivers available
for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport
and our driver download page www.hp.com/support/DL365G5.
Rack
Airflow Requirements
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors. CAUTION: If a third-party
rack is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
Front
and rear doors: If your 42U server rack includes closing front and rear doors,
you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from
top to bottom to permit adequate airflow (equivalent to the required 64 percent
open area for ventilation).
Side: The clearance
between the installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in
the rack. This arrangement ensures proper airflow. Using a rack without blanking
panels results in improper cooling that can lead to thermal damage.
NOTE: For
additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the Support
section at the following URL: www.hp.com/servers/dl365.
Rack Kit
Quick deploy rail system provides tool-free support for racks with square
or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and
HP series), with an adjustment range of 24" - 36". The ambidextrous
cable management arm can be mounted on either the left or right side for
improved cable management.
Telco Rack Support
Support for all 2-post Telco racks requires the use of the standard rack
kit and an additional option kit from Rack Solutions at: http://www.racksolutions.com/hp/
Factory
Express Portfolio for Servers and Storage
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific
server model please contact your sales representative or go to: http://www.hp.com/go/factory-express.
HP Enterprise Configurator
The HP eConfigure-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance. http://www.hp.com/products/configurator.
Service
and Support
HP Care Pack
services provide total care and support expertise with committed response designed
to meet your IT and business needs.
HP Care Pack services include coverage
for the HP branded hardware options qualified for the server and purchased at
the same time or afterward that are internal to the enclosure. This also includes
the 22" and smaller external monitors and tower UPS options up to 3kVA. These
items will be covered at the same service level and for the same coverage period
as the server. Coverage of UPS Battery is not included, and standard warranty
terms & conditions apply. For servers or storage systems installed within
a rack, service also covers all HP qualified rack options installed within the
same rack.
To fully capitalize on your HP ProLiant servers' capabilities
requires a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi vender
support solutions, provides a range of support services designed to meet the varying
needs of your business. Whether an SMB, or large global corporation, HP has a
ProLiant server support offer to help you speedily deploy and maximize system
uptime.
Recommended Service - simplify ProLiant solution implementation,
maintenance, and management.
Support: 3-Year 4-Hour response
24x7 Same Business Day Coverage only
Deployment Service: Installation
and Start up only
Enhanced Service - optimize service level to increase
IT performance and availability.
Support: 3-Year Support
Plus 24 only
Refer to the information on "Installation &
Start-Up" for service on ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays.
NOTE:
For the Standard Features shipped in the "Factory Integrated Models",
please see the "Configuration Information - Factory Integrated Models"
section.
Configuration Information - Factory Integrated Models
NOTE: This section lists some of the
steps required to configure a Factory Integrated Model. To ensure only
valid configurations are ordered, HP recommends the use of an HP approved
configurator. Contact your local sales representative for information
on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard
models listed above. Configure-to-order servers must start with a CTO
Chassis. NOTE: FIO indicates that this option only available as a Factory
Installable Option.
Step
1: Base Configuration (choose one of the following configurable models)
Models
HP
ProLiant DL365 G5 Rack CTO Chassis
454269-B21
Factory
Integrated Model ships with:
Two embedded NC373i Multifunction Gigabit Server Adapters
Integrated Lights-Out 2 (iLO 2) embedded
1 full-length and 1 low-profile x8 PCI-Express slots
9 fans; N+1 fan redundancy
(1) 700W power supply, redundant optional
Rack (1U), (1.75 in/4.45 cm)
Step
2: Choose Required Options (only one of the following from each list unless otherwise
noted)
HP
Smart Array P600/256 BBWC Controller NOTE:
Requires PCI-X Riser option (PN 405154-B21). NOTE: Requires HP
SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
The HP ProLiant
DL365 G5 performance packs are necessary to configure a HP ProLiant DL365
G5 Performance Model. HP ProLiant DL365 G5 Performance model includes the
latest performance technologies and enterprise class availability features
pre-installed for convenience and value. The performance pack includes a
2nd processor, redundant power supplies, Smart Array P400i Controller with
256MB of BBWC, and storage cable to enable the all 6 disk drive bays. NOTE: 331903-B21 Slimline CD-RW/DVD-ROM
Combo Drive Option Kit should also be selected along with the Performance
Pack skus below to achieve parity to the HP ProLiant DL365 G5 Performance
Models.
HP DL365G5 X2356
HPM FIO Perf Pack
448448-B21
HP DL365G5 X2384
HPM FIO Perf Pack
510151-B21
Step
4: Choose Additional Options for Factory Integration
NOTE:
For additional options, please refer to the "Core Options" and
"Additional Options" section below.
NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two gigabyte (2
GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber
transceivers and cables for fiber-optic environments must be purchased separately.
HP Insight Control
Environment, No Media 1-Server License including 1 year of 24x7 Technical
Support and Updates NOTE: Customer will receive a license
entitlement certificate, which must be redeemed online or via fax in order
to obtain the license activation key(s). Includes one year of 24 x 7 HP
Software Technical Support and Update Service.
452148-B22
HP Insight Control
Management Software Media Kit NOTE: Insight Software DVD media
without licenses. Contains HP System Insight Manager and Insight software
products and components licensed by the Insight Control suite. Uses an integrated
installer to perform quick and accurate software installation and updates.
HP Insight Control
suite for Linux, Media pack (DVD) - No licenses included NOTE: This optional Media pack DVD
contains the ISO image for HP Insight Control Environment for Linux, HP
System Insight Manager, HP Insight Power Manager, HP Insight Virtual Machine
Management software, and an integrated installer. Servers must be acquired
separately. NOTE: This Media pack is optional because the latest ISO image and
latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux
(click on Download button).
464422-B22
HP Insight Control
suite for Linux, No Media, 1-Server license, including one year of 24x7
Technical Support and Updates NOTE: This part number can be used
to purchase one (1) license with a single activation key. Customer will
receive a printed license entitlement certificate via physical shipment.
The license entitlement certificate must be redeemed online or via fax in
order to obtain the license activation key(s). Includes one year of 24 x
7 HP Software Technical Support and Update Service. NOTE: One certificate is shipped for each license.
HP Integrated Lights-Out
Advanced, No Media, 1-Server License, including 1 year of 24x7 Technical
Support and Updates NOTE: This license allows 1 server
to be deployed and managed via HP iLO Advanced. Customer will receive a
printed license entitlement certificate via physical shipment. The license
entitlement certificate must be redeemed online or via fax in order to obtain
the license activation key(s). Includes one year of 24 x 7 HP Software Technical
Support Service NOTE: For additional license kits, including electronic delivery
options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html
512485-B21
HP Insight Rapid
Deployment software
HP Insight Rapid
Deployment software No Media 1-Server License, including 1 year of 24x7
Technical Support and Updates NOTE: This license allows 1 server
to be deployed and managed via RDP. Customer will receive a printed license
entitlement certificate via physical shipment. The license entitlement certificate
must be redeemed online or via fax in order to obtain the license activation
key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional license kits, including electronic delivery
options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html
512MB BBWC NOTE: When used with the embedded
HP Smart Array P410i controller, this battery module also requires a 24
inch SFP Battery Cable (496029-B21).
HP 8 Internal Port SAS HBA with
RAID NOTE: Supports SAS and SATA disk
drive. RAID 0,1 supported. Transfer rate: 1.5 Gb/s SATA, 3 Gb/s SAS. NOTE: When using the 8 Internal Port SAS HBA with SATA Hard Drives,
1.5G SATA Hard Drives are required.
HP Mini SAS 4i 13.4 inch/0.35
m cable NOTE: Used to connect Smart Array
P400i to DL365 5th and 6th drive bays.
399546-B21
HP SAS 4i to Mini SAS 4i 31 inch/.79
meter cable NOTE: Used to connect SA-P600, SA-P400,
SA-E200 Controllers to the HP ProLiant DL365 G5 drive backplane. This kit
supports all six drive bays.
411100-B21
SCSI Controllers for External
Drive/Storage Support
Smart Array 6402/128 Controller NOTE: For support of external drives
only.
HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT
160 USB tape drive.
AG703A
SAS Rack-Mount
Tape Solutions NOTE: HP recommends purchasing the
HP SC44Ge HBA ( 416096-B21) for a dedicated SAS HBA for tape.
HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4
Ultrium 1760 SAS tape drive.
EH946A
HP StorageWorks 1U SAS Rack-Mount
Kit NOTE: Supports up to (2) half-height
SAS tape drives.
AE459A
HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount
Kit (AE459A)
DW085A
HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS
Rack-Mount Kit (AE459A)
EH847A
NOTE: For an up-to-date
listing of the latest O/S and software support details for HP Ultrium tape
drives, please visit: http://www.hp.com/go/connect
HP StorageWorks 1/8 G2 Tape Autoloader
HP StorageWorks 1/8 G2 LTO-4 Ultrium
1760 SAS Tape Autoloader
AK377A
HP StorageWorks 1/8 G2 LTO-3 Ultrium
920 SAS Autoloader
AH558A
HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8
G2 Tape Autoloaders in a standard 19-inch rack; includes rails and rackmount
instructions.
AH166A
NOTE: Please reference
the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation
for additional information needed to create a complete solution.
HP StorageWorks MSL2024 Tape Library
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1760 SAS Drive Library
AK378A
HP StorageWorks MSL2024 1 LTO-3
Ultrium 920 SAS Drive Library
AH559A
HP StorageWorks MSL4048 Tape Library
HP StorageWorks MSL4048 2 LTO-4
Ultrium 1760 SAS Drive Library
AK380A
HP StorageWorks MSL4048 1 LTO-3
Ultrium 920 SAS Drive Library
AH560A
NOTE: Please reference
the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at: http://www.hp.com/go/ebs.
Disk-Based Backup
RDX Removable Disk Backup
HP StorageWorks RDX500 External
Removable Disk Backup System NOTE: 500GB of Disk Storage.
10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping
requirements, AF044A is only orderable through HP Factory Express. It is
not for direct sales. Customer site surveys are required before an order
is approved. CTO orders may require additional lead time.
AF044A
10647 G2 (47U) Rack Cabinet 1200mm
Deep - Pallet
AF045A
NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment
installed (by custom systems, VARs and Channels).
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm.
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.
NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.
Rack Kits
1U Cable Management Arm NOTE: Package contains two cable
management arms.
365403-B21
USB Options
HP USB 2-Button Optical Scroll
Mouse (Carbonite/Silver)
HP 4GB USB Flash Media Key Kit NOTE: Blank USB media device is supported
for use with ProLiant iVirtualization. USB media must be installed in the
internal slot of the ProLiant server. Learn more at http://www.hp.com/go/proliantvirtualization.
580385-B21
Service and Support Offerings (HP
Care Pack Services)
Hardware
Services 4-Hour On-site Service
4-Hour On-site Service, 5-Day
x 13-Hour Coverage, 3 Years, Electronic
U4496E
4-Hour On-site Service, 7-Day
x 24-Hour Coverage, 3 Years, Electronic
U4497E
Hardware Services 6-Hour Call
to Repair On-site Service
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
U4498E
Hardware Services Next Business
Day On-Site Service
Hardware Installation, Electronic
U4506E
Installation & Start-Up of
a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or
Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays,
Electronic
U4507E
Support Plus
Onsite HW support, 8am-9pm, M-F,
4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion,
8am-9pm, M-F 2hr response time excl. HP holidays, Electronic
U4508E
Support Plus 24
Onsite HW support 24x7, 4hr response
and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr
response time incl. HP holidays, Electronic
U4509E
Onsite HW support 24x7, 4hr response
and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response
time incl. HP holidays, Electronic
U6310E
Onsite HW support 24x7, 4hr response
and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7
2hr response time incl. HP holidays, Electronic
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models".
HP ProLiant DL365 G5 Models
Standard Memory NOTE: One of the following depending
on model:
Performance Models: 4 GB PC2-5300 DDR2 DIMMs (667 MHz) installed (4 x
1 GB)
Base and Entry Models: 2 GB PC2-5300 DDR2 DIMMs (667 MHz) installed (2
x 1 GB)
High Efficiency Models: 2 GB PC2-5300 DDR2 Low Power DIMMs (667MHz) installed
(2 x 1 GB)
Upgrading Memory and Memory Interleaving
DIMMs must be installed in identical pairs. Bank interleaving is automatically
enabled on a processor node under the following conditions:
1) Four single ranked DIMMs populated per node (4 x
512 MB or 4 x 1 GB for example) yields 2-way bank interleaving.
2) Two dual ranked DIMMs populated per node (2 x 2 GB or 2 x 4 GB for
example) yields 2-way bank interleaving.
3) Four dual ranked DIMMs populated per node (4 x 2 GB or 4 x 4 GB for
example) yields 4-way bank interleaving.
If single and dual ranked DIMMs are mixed on the same node, bank interleaving
will not be enabled.
Node interleaving can be configured via RBSU if both processors have the
same memory footprint and is independent of bank interleaving.
Standard Memory Plus Optional Memory
Up to 26 GB memory is available with the standard memory of 1 GB and the
optional installation of PC2-5300 DDR2 DIMMs (667 MHz) memory kits. -
6 slots would be available, and potentially could be filled with 4GB DIMM's.
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 512
MB of memory and the optional installation of PC2-5300 DDR2 DIMMs (667
MHz) memory kits.
NOTE: DIMM
banks are active only when the corresponding processor socket is populated. NOTE: Chart does not represent all possible configurations.
Memory
Slot
1
2
3
4
5
6
7
8
Standard
(Base, Entry, and Performance Models)
2 GB
1 GB
1 GB
Empty
Empty
Empty
Empty
Empty
Empty
Optional
26 GB
1 GB
1 GB
4
GB
4 GB
4 GB
4
GB
4 GB
4 GB
Maximum
32
GB
4 GB
4 GB
4
GB
4 GB
4 GB
4
GB
4 GB
4 GB
Following
are memory options available from HP:
1 GB REG PC2-5300
2 x 512 MB Single Rank Kit NOTE: Supported
on 2352, 2354, and 2356 processor models.
Hard Drives NOTE: The components of a storage
subsystem (e.g. the drive, the HBA/controller, firmware, and the server
backplane) should operate at the same data transfer rate or the system bandwidth
will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
SAS Hot Plug SFF Enterprise
(ENT) Drives
Quantity
Supported
Position
Supported
Controller
300GB 6G SAS 10K DP 300GB 3G SAS
10K DP 146GB 6G SAS 15K DP 146GB 6G SAS 10K DP
146GB 3G SAS 15K DP
146GB 3G SAS 10K DP
72GB 6G SAS 15K DP
72GB 3G SAS 15K DP
72GB 3G SAS 10K DP
6
1-6
HP Smart Array E200i/64 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB BBWC Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/ZM Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller Please see NOTES below regarding
hard drive quantity supported by Smart Array Controller.
NOTE:
The Smart Array E200i Controller can support a maximum of 4 hard drives. NOTE: The Smart Array P400 Controller can support a maximum of 6
hard drives. To support drives 5 and 6, the optional HP Mini SAS 4i 13.4
inch/0.35 m cable is required (PN 399546-B21). NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini
SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
SAS Hot Plug SFF Midline
(MDL) Drives
Quantity
Supported
Position
Supported
Controller
500GB 6G SAS 7.2K DP
6
1-6
HP Smart Array E200i/64 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB BBWC Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/ZM Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller Please see NOTES below regarding
hard drive quantity supported by Smart Array Controller.
NOTE:
The Smart Array E200i Controller can support a maximum of 4 hard drives. NOTE: The Smart Array P400 Controller can support a maximum of 6
hard drives. To support drives 5 and 6, the optional HP Mini SAS 4i 13.4
inch/0.35 m cable is required (PN 399546-B21). NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini
SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
SATA Hot Plug SFF
Midline (MDL) Drives
Quantity
Supported
Position
Supported
Controller
500GB 3G SATA 7.2K
160GB 3G SATA 7.2K
6
1-6
HP 8 Internal Port SAS HBA with
RAID NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the 8 Internal Port SAS HBA with SATA Hard Drives,
1.5G SATA Hard Drives are required.
HP SC44Ge Host Bus Adapter NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard
Drives are required.
HP Smart Array E200i/64 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/ZM Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
NOTE:
The Smart Array E200i Controller can support a maximum of 4 hard drives. NOTE: The Smart Array P400 Controller can support a maximum of 6
hard drives. To support drives 5 and 6, the optional HP Mini SAS 4i 13.4
inch/0.35 m cable is required (PN 399546-B21). NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini
SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
SATA Hot Plug SFF
Entry (ETY) Drives
Quantity
Supported
Position
Supported
Controller
250GB 3G SATA 5.4K
120GB 1.5G SATA 5.4K
6
1-6
HP 8 Internal Port SAS HBA with
RAID NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the 8 Internal Port
SAS HBA with SATA Hard Drives, 1.5G SATA Hard Drives are required.
HP SC44Ge Host Bus Adapter NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the SC44Ge with
SATA Hard Drives, 1.5G SATA Hard Drives are required.
HP Smart Array E200i/64 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/ZM Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
NOTE:
The Smart Array E200i Controller can support a maximum of 4 hard drives. NOTE: The Smart Array P400 Controller can support a maximum of 6
hard drives. To support drives 5 and 6, the optional HP Mini SAS 4i 13.4
inch/0.35 m cable is required (PN 399546-B21). NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini
SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
SATA Hot Plug Midline
(MDL) Solid State Drives
Quantity
Supported
Position
Supported
Controller
60GB 3.0G SATA SSD
120GB 3.0G SATA SSD
6
1-6
HP 8 Internal Port SAS HBA with
RAID NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the 8 Internal Port SAS HBA with SATA Hard Drives,
1.5G SATA Hard Drives are required.
HP SC44Ge Host Bus Adapter NOTE: Transfer rate: 1.5 Gb/s SATA,
3 Gb/s SAS. NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard
Drives are required.
HP Smart Array E200i/64 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/ZM Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
External Storage
Quantity
Supported
Position
Supported
Host Controller or Adapter
20 Modular Smart Array
Please see the QuickSpecs to determine configuration
requirements
HP StorageWorks USB Tape Drives,
External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount
Kit
External
USB 2.0 Port
N/A
HP
StorageWorks SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium
448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium
1840 SAS 1U Rack-Mount Kit 3U Rack-Mount Kit
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL365 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL365 G5
- Click on: "Power Calculator" link. (You may need to scroll down
to see it)
Power Supply Output
(per power supply)
Rated Steady-State Power
700 W
System Inlet Temperature
Operating
10° to 35°C (50° to
95°F) at sea level with an altitude derating of 1.0°C per every
305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050
m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of
options installed.
System performance may be reduced if operating with a fan fault or above
30°C (86°F).
Storage
-30° to 60°C - Maximum
rate of change is 20°C/Hr.
Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh),
28°C maximum wet bulb temperature
Storage
5 to 95% relative humidity (Rh),
38.7°C maximum wet bulb temperature.
Acoustic Noise
Listed are the declared
A-Weighted sound power levels (LWAd) and declared average bystander position
A-Weighted sound pressure levels (LpAm) when the product is operating in
a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle:
L WAd (BELS)
6.4
L pAm (dBA)
49
Operating:
L WAd (BELS)
6.4
L pAm (dBA)
49
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC
CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3;
EN 60950-1; IEC 60950-1
NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is
eligible to bear the appropriate compliance logos and statements.
Smart
Array E200i Controller
Disk
Drive and Enclosure Interface
3
G SAS (Serial Attached SCSI)
1.5
G SATA (Serial Advanced Technology Attachment)
SAS
Connectors
2 internal (SFF8484)
x4 wide port connectors
Cache
Memory Speed
DDR-1/266 MHz provides
up to 4.2 GB/s maximum bandwidth.
Server
Interface
x4 2.5 G PCIe provides
2 GB/s maximum bandwidth.
SAS
Speed
x8 3 G SAS provides 2.4 GB/s
maximum bandwidth.
Cache
Memory
40-bit 64 MB or 128 MB cache:
ECC protection, battery-backed, and transportable
Logical
Volumes Supported
Up to 32 logical
volumes
Maximum Volume
Capacity
3TB (6 x 500 GB)
Host Memory Addressing
64-bit,
supporting greater than 4 GB server memory space
RAID
Support
RAID 5 (Distributed Data
Guarding) requires 128 MB BBWC option
RAID
1+0 (Striping & Mirroring)
RAID
0 (Striping)
Upgradeable
Firmware
Upgradeable Firmware
Two embedded NC373i Multifunction
Gigabit Server Adapters
Hewlett-Packard
offers end-of-life HP product return, trade-in, and recycling programs in many
geographic areas. For trade-in information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC)
requires manufacturers to provide treatment information for each product type
for use by treatment facilities. This information (product disassembly instructions)
is posted on the Hewlett Packard web site at: http://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.