HP ProLiant Lights Out 100i Remote Management support
ROM Setup Utility
USB Ports:
Four USB ports (two front, two rear)
Optical Drive:
Support for one (optional): CD-ROM, DVD-ROM, DVD RW, DVD/CD RW
Power Supply:
650W Power Supply (Non-Hot Plug, Autoswitching)
Form Factor:
1U rack models
Deployment/Serviceability:
Tool-less access to all system components for easy in rack serviceability
Warranty:
This product is covered by a global limited warranty and supported
by HP Services and a worldwide network of HP Authorized Channel
Partners. Hardware diagnostic support and repair is available for
one year from date of purchase. Support for software and initial
setup is available for 90 days from date of purchase. Additional
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP
Care Pack services or customized service agreements. Certain restrictions
and exclusions apply. SATA hard drives have a one year warranty.
NOTE: For a brief, printer friendly data sheet
that describes this product and informs you of the essential capabilities and
specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-8885ENW.pdf NOTE: For the Standard Features shipped in the "Factory Integrated
Models", please see the "Configuration Information - Factory Integrated
Models" section.
Processor One of the following depending on Model
AMD
Opteron™ processor Model 2220 (2.8 GHz (95W)
AMD
Opteron™ processor Model 2218 (2.6 GHz (95W)
AMD
Opteron™ processor Model 2216 (2.4 GHz (95W)
AMD
Opteron™ processor Model 2216 HE (2.4 GHz (68W)
AMD
Opteron™ processor Model 2214 HE (2.2 GHz (68W)
AMD
Opteron™ processor Model 2210 HE (1.8 GHz (68W)
AMD
Opteron™ processor Model 2210 (1.8 GHz (95W)
Upgradeability
Upgradeable to two processors
Chipset
ServerWorks HT2100 and HT1000
Cache Memory
1MB Level 2 cache per core
Memory Protection
Memory mirroring with Advanced
ECC capabilities
Memory One of the following depending on Model
Type
REG PC2-5300 DIMMs
(DDR2-667)
Standard (Depending on model)
1 GB
2 GB
4 GB
(2 x 512 MB)
(2 x 1 GB)
(2 x 2 GB)
Maximum
32 GB
(8 x 4 GB)
Network
Controller
NC326i PCIe Dual Port Gigabit
Server Adapter
Expansion Slots
Slot Number
Bus Speed
Bus Number*
Device Number**
Hot Plug
(Y/N)
PCI Voltage
Notes
1
x16 PCI-Express
3
0
No
3.3 volts
Full length, full height
1
HTX
9
1
No
3.3 volts
Full length, full height
2
x4 PCI-Express
6
0
No
3.3 volts
Low Profile
2
4-bit, 133MHz PCI-X
2
1
No
3.3 volts
Low Profile
*
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number.
**
Slots are enumerated differently based on OS. MS OS's enumerate from lowest
to highest Device ID by bus (starting with the lowest bus).
Storage Controller
Non-Hot Plug SATA Models
HP Embedded SATA Controller
Hot Plug SATA/SAS Models
HP 8 Internal Port SAS HBA with
RAID 0,1
NOTE: A diskette
drive is needed to install storage controller drivers during a Windows operating
system installation from CD.
Server Management
Stand Alone Software Product and ProLiant Essentials
HP Systems Insight Manager
HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible standards-based environment
to centrally manage servers, storage and other infrastructure devices, (both
HP and non-HP) across multiple operating system platforms.
ProLiant Essentials Rapid Deployment
Pack
Rapid Deployment Pack (RDP)
extends HP Systems Insight Manager with a complete deployment solution for
HP ProLiant servers. RDP provides a central location to configure server
hardware, deploy Windows, Linux and VMware ESX operating environments and
install HP ProLiant Support Pack drivers using images and scripted profiles.
For more information, visit: http://www.hp.com/go/rdp
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to: http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
HP Lights-Out 100i Remote Management
HP
Lights-Out 100i Remote Management delivers affordable, entry level remote
management capabilities for HP ProLiant 100 Series servers with embedded
LO100i. It allows customers or their service providers to remotely manage
ProLiant 100 Series servers remotely over a LAN or the Internet and consists
of the following:
LO100i Standard is
embedded remote management and provides basic remote control via telnet,
browser, and IPMI 2.0 and SMASH
LO100i Select Pack
License are upgrades for essential, secure, remote control, serial console
and virtual media
LO100i Advanced Pack
License are upgrades for all the features of LO100i Select plus Virtual
KVM (graphical hardware-based, remote console)
Core
Infrastructure Management
Subscriber's
Choice
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription service that
provides software and driver change notifications for ProLiant products. Sign
up at: http://www.hp.com/go/subscriberschoice and
customize your profile to receive various new alerts as they become available,
on a weekly or monthly basis.
ROMPaq software and latest drivers
The
latest software, drivers, and firmware fully optimized and tested for your ProLiant
server and options, available through ProLiant Support Packs or downloaded from
software and drivers download pages website at: http://www.hp.com/go/support.
Industry Standard
Compliance
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0 Compliant
Manageability
HP ProLiant Lights Out 100i
Remote Management standard
3 system fans ship standard;
Non-hot plug, Non-redundant
OS
Support
Microsoft Windows 2003
and Microsoft Windows 2003/R2 Standard Edition (32-bit) Microsoft Windows
2003 and Microsoft Windows 2003/R2 Enterprise Edition (32-bit) Microsoft Windows
2003 and Microsoft Windows 2003/R2 Web Edition (32-bit) Microsoft Windows
2003 and Microsoft Windows 2003/R2 for Extended Systems Standard Edition (64-bit)
Microsoft Windows 2003 and Microsoft Windows 2003/R2 for Extended Systems Enterprise
Edition (64-bit) Microsoft Windows Server 2008 Red Hat Enterprise Linux
SUSE Linux Enterprise Server
Rack
10000 series Cabinets The increasing power of new high-performance processor
technology requires increased cooling efficiency for rack-mounted servers. The
10000 Series Racks provide enhanced airflow for maximum cooling, allowing these
racks to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional requirements to
ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear
doors, you must allow 5,350 sq cm (830 square inches) of hole evenly distributed
from top to bottom to permit adequate airflow (equivalent to the required 64 percent
open area for ventilation). Side: The clearance between the installed rack
component and the side panels of the rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking
panels to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in improper
cooling that can lead to thermal damage.
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the Support
section at the following URL: http://h18000.www.hp.com/products/servers/proliantDL145/index.html
Telco Rack Support
Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack
kit and an additional option kit from Rack Solutions. http://www.racksolutions.com/hp
HP Factory Express Capability
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of servers
and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem,
HP 9000 servers as well as the MSAxxx, VA7xxx, EVA, XP, rackable tape libraries
and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to: http://www.hp.com/go/factory-express.
HP Enterprise Configurator
The HP eCo-Enterprise Configurator now provides factory default racking
for our HP hardware portfolio. This approach is aligned with our strategic
direction to meet the needs and expectations of our valued customers.
If you require "custom" rack configuration, please contact HP's
Customer Business Center or an Authorized Partner for assistance.
Service and Support
HP Care Pack Services provide total care and support expertise with committed
response designed to meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.
To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
Recommended Service - Simplify ProLiant solution implementation,
maintenance and management.
Support Service -3 Year, 9x5 Next Business Day coverage, excluding
HP holidays only
Deployment Service - Hardware Installation only
Enhanced Service - Optimize service level to increase IT performance
and availability
Support Service - 3 Year 13x5 Same Business Day, 4-Hour response
coverage
Deployment Service - Installation and Start-up only
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.
NOTE:
High Performance Computing (HPC) interconnect technologies are available
for the DL145 under the Cluster Platform product portfolio. These high-speed
interconnects are fully supported by HP when they are part of these configure
to order clusters. Solutions can be defined with a lot of flexibility with
the help of configuration tools. Please visit the following URL to configure
HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
http://www.hp.com/techservers/clusters/ucp/index.html
Configuration Information - Factory Integrated Models
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for additional information. Contact your local sales representative for information
on CTO product offerings and requirements. NOTE: HP does not allow
factory integration of options into standard models listed above. Configure-to-order
servers must start with a CTO Chassis. NOTE: This product offering
does not support HP Factory Express Server Configuration Level 1. NOTE:
FIO indicates that this option is a Factory Installable Option.
Step 1: Base Configuration
Non-Hot
Plug Model
HP ProLiant DL145 G3 Non- Hot Plug
SATA Rack Chassis
411588-B21
Factory Integrated Model ships
with:
NC326i PCIe Dual Port Gigabit
Server Adapter
Two available PCI-Express slots,
including one full-length/full height and one low-profile/half height slot
HP
Embedded SATA Controller
650 Watt Power Supply
3 Non-Hot Plug Blowers
Rack (1U), (1.75 in / 4.45 cm)
Hot Plug Model
HP
ProLiant DL145 G3 Hot Plug SATA/SAS Rack Chassis
411590-B21
Factory
Integrated Model ships with:
NC326i
PCIe Dual Port Gigabit Server Adapter
One
available PCI-Express slot, (full-length/full height), the low-profile/half height
slot houses the SATA/SAS storage controller
One
HP 8 Internal Port SAS Host Bus Adapter with RAID
One
HP SATA/SAS Host Cable Kit
One Hot Plug Backplane Option
Kit
650 Watt Power Supply
3 Non-Hot Plug Blowers
Rack (1U), (1.75 in / 4.45 cm)
Step
2: Choose Required Options (only one of the following from each list unless otherwise
noted)
Base Processors
AMD Opteron™ processor
Model 2220 (2.8 GHz (95W) NOTE: If
2 processors are desired, select one 440721-B21 and one 440721-B21.
440721-B21
AMD
Opteron™ processor Model 2218 - 2.6 GHz (95W) NOTE:
If 2 processors are desired, select one 411606-B21 and one 411606-B21.
411606-B21
AMD
Opteron™ processor Model 2216 - 2.4 GHz (95W) NOTE:
If 2 processors are desired, select one 435014-B21 and one 435014-B21.
435014-B21
AMD
Opteron™ processor Model 2216 HE - 2.4 GHz (68W) NOTE:
If 2 processors are desired, select one 411616-B21 and one 411616-B21.
411616-B21
AMD
Opteron™ processor Model 2214 HE - 2.2 GHz (68W) NOTE:
If 2 processors are desired, select one 411605-B21 and one 411605-B21.
411605-B21
AMD
Opteron™ processor Model 2212 - 1.8 GHz (95W) NOTE:
If 2 processors are desired, select one 411615-B21 and one 411615-B21.
411615-B21
AMD
Opteron™ processor Model 2210 HE - 1.8 GHz (68W) NOTE:
If 2 processors are desired, select one 411604-B21 and one 4116045-B21.
HP 8 Internal Port SAS HBA with
RAID
NOTE: For use with Hot Plug SATA/SAS models only
NOTE: The selection of the HP 8 Internal Port SAS HBA with RAID requires
the purchase of the PCI-X Riser Option kit (P/N 411625-B21)
HP SATA/SAS Host Cable Kit
NOTE: For use with Hot Plug SATA/SAS models only
389650-B21
HP Smart Array E500/256MB Controller NOTE: Selection of the E500 with
the E200 will prevent installation of the E500 battery-backed write cache
module.
HP Smart Array E200/128 BBWC Controller NOTE: Selection of the E500 with
the E200 will prevent installation of the E500 battery-backed write cache
module.
HP Single Channel U320 SCSI Controller
NOTE: The selection of the 64-Bit/133-MHz Single Channel Ultra 320 SCSI
HBA G2 requires the purchase of the PCI-X Riser Option kit (P/N 411625-B21)
Step 3: Choose Additional Options
for Factory Integration
NOTE: For additional
options, please refer to the "Options" section below. Some options
may not be available for factory integration. Please contact an HP sales
representative for additional information.
Server Management
Stand Alone Software Product – ProLiant Essentials
NOTE: Electronic
licensing options are available for Insight Control suites and select ProLiant
Essentials software products. Please see the appropriate Insight Control
and ProLiant Essentials QuickSpecs for additional information.
Deploy
ProLiant Essentials Rapid Deployment
Pack
ProLiant Essentials Rapid Deployment
Pack No Media 1-Server License including 1 year of 24x7 Technical Support
and Updates NOTE: This license allows 1 server
to be deployed and managed via RDP
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to: http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: http://www.hp.com/servers/proliantessentials.
Control
Integrated Lights-Out 100i
Select Pack and Advanced Pack
NOTE:
When purchasing systems with the 500 GB Non-Hot Plug SATA drives, please reference
the Configuration Information Section of this QuickSpecs to order via Configuration
to Order.
Serial-ATA (SATA) Hot
Plug Hard Drives (SATA/SAS Hot Plug Models Only)
NOTE: The purchase
of SAS HBA or array controller is required.
Graphic Cards
NVIDIA Quadro FX3500 256MB PCIe
435681-B21
NVIDIA Quadro FX1500 256MB PCIe
435703-B21
NOTE:
At this time, these graphic cards are supported on Linux and Windows.
Optical Drives
DVD-ROM Drive (optional)
432878-B21
DVD/CD RW Drive (optional)
432880-B21
Multibay II DVD/CD-RW Combo Drive
NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive, (P/N PA850A), the USB 2.0 Multibay II Cradle (P/N
PA509A) is required.
PA850A
USB 2.0 MultiBay II Cradle, External NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive, (P/N 850A), the USB 2.0 Multibay II Cradle, (P/N
PA509A) is required.
HP 8 Internal Port SAS HBA with
RAID NOTE: For use with Hot Plug SATA/SAS
models only NOTE: The selection of the HP 8 Internal Port SAS HBA with RAID requires
the purchase of the PCI-X Riser Option kit (P/N 411625-B21).
HP SATA/SAS Host Cable Kit NOTE: For use with Hot Plug SATA/SAS
models only.
389650-B21
HP Smart Array E500/256MB Controller NOTE: Selection of the E500 with
the E200 will prevent installation of the E500 battery-backed write cache
module.
HP Smart Array E200/128 BBWC Controller NOTE: Selection of the E500 with
the E200 will prevent installation of the E500 battery-backed write cache
module.
64-Bit/133-MHz Single Channel
Ultra320 SCSI HBA G2 NOTE: The selection of the 64-Bit/133-MHz
Single Channel Ultra 320 SCSI HBA G2 requires the purchase of the PCI-X
Riser Option kit (P/N 411625-B21)
NOTE: For HPC
interconnect adapters please see the HPC Interconnect section of this QuickSpecs.
Rack Kits
1U Cable Management Arm NOTE: Package contains two cable
management arms.
365403-B21
Tape Drives
USB Tape Drives
HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 72 USB Tape Drive
AG594A
HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive
AG703A
Ultrium External Tape Drives
HP StorageWorks LTO-1 Ultrium
232 Internal Tape Drive (Carbonite) NOTE:
HP recommends combining this tape drive with the 1U SCSI Rack-Mount kit ( A7445B)
for a complete rack-mount solution.
HP StorageWorks 1U SCSI Rack-Mount
kit NOTE: The 1U Rack-Mount Kit can
support up to (2) half-height tape drives and is compatible with multiple Single-Ended
and LVD SCSI tape drives including the DAT 40, DAT 72, DAT 160, DLT VS160, LTO-1
Ultrium 232, LTO-2 Ultrium 448 and LTO-3 Ultrium 920 tape drives.
HP StorageWorks 1U USB Rack-Mount
Kit NOTE: The 1U USB Rack-Mount Kit
can support up to (2) half-height tape drives and is compatible with the DAT 40
USB, DAT 72 USB and DAT 160 USB tape drives.
NOTE:
For additional information regarding KVM switches, Serial Console servers, rack
mount monitors, keyboards and all related options please see the following URL:http://www.hp.com/go/kvm
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables can
be found at the following URL: http://www.hp.com/go/kvm
NOTE:
For
additional information regarding KVM switches, Serial Console servers, rack mount
monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models".
HP ProLiant DL145
G3 (all models)
Standard Memory
1 GB (2 x 512 MB) PC2-5300 DIMM memory, with Advanced ECC Capabilities memory
installed.
2 GB (2 x 1 GB) PC2-5300 DIMM memory, with Advanced ECC Capabilities memory
installed.
4 GB (2 x 2GB) PC2-5300 DIMM memory, with Advanced ECC Capabilities memory
installed.
Maximum Memory
Up to 32GB memory is available with the optional installation of PC2-5300
Registered DIMM memory kits.
Memory should be installed in pairs and matched for optimum performance.
NOTE:
Chart does not represent all possible memory configurations.
High voltage power cord
ships standard with all part numbers. NOTE:
ProLiant DL servers no longer ship standard with NEMA power cords (187335-001)
that allow connection to 110V US wall outlets in a home or office. ProLiant DL
servers are primarily connected to PDU's in data center racks so they now ship
standard with only a PDU power cord (416151-B21). If a user wishes to power a
ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord (187335-001)
must be ordered separately.
HP 8 Internal Port SAS HBA with RAID ( 347786-B21)
Drives
Supported
Up to 2 SATA/SAS
drives
Channels
8
Storage Capacity
600
GB
Data Transfer
Method
64-bit/133MHz PCI-X
Maximum Host Bus Transfer
Rate
1.06 Gb/sec
Maximum SAS transfer rate
300
MB/sec per port
Protocols
Supported
SSP, STP, SMP
Internal Connectors
2
SAS
NC326i
PCIe Dual Port Gigabit Server Adapter
Network
Interface
10Base-T/100Base-TX/1000Base-TX
Compatibility
IEEE
802.3 10Base-T
IEEE
802.3 1000Base-T
IEEE
802.3 100Base-TX
Data
Transfer Method
64-bit,
133MHz PCI(X)1.0
Network
Transfer Rate
10Base-T
(Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20
Mb/s
100Base-TX (Half-Duplex)
100
Mb/s
100Base-TX (Full-Duplex)
200
Mb/s
1000Base-TX (Half
and Full-Duplex)
2000
Mb/s
Connector
RJ-45
Cable Support
10Base-T
Categories
3, 4 or 5 UTP; up to 328 ft (100 m)
10/100/1000Base-TX
Category
5 UTP (2 Pair); up to 328 ft (100 m)
Environment-friendly
Products and Approach
End-of-life
Management and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner.
The EU WEEE directive
(2002/95/EC) requires manufacturers to provide treatment information for each
product type for use by treatment facilities. This information (product disassembly
instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.